100Cr6 / 52100 Bearings for Electric Motors & Drives

Most motor bearings are 52100, and that is not a compromise: the grease-life calculation the motor was rated on assumes this steel. Electric Motors & Drives duty is continuous speed, long grease life and shaft voltages from PWM drives; the material is what decides whether the bearing survives it.

10–120 mm bore range59–65 HRC120 °C (200 °C stabilised)Mill certificates on request
Short answer. Use 52100 up to 120 °C housing temperature. At 59–65 HRC it gives the highest dynamic capacity per millimetre of section, and a C3 clearance with a polyurea grease reaches the 20,000–40,000 h grease life the motor is sold on.

Key facts

This grade in this duty, in eight rows.
Industry duty1,500–6,000 rpm continuous, up to 20,000 rpm on servo drives
Typical mediacooling air, dust, occasional washdown
Housing temperature−20 to +120 °C
Material and gradethrough-hardened chrome steel — 100Cr6 / 52100
Hardness59–65 HRC
Temperature ceiling120 °C (200 °C stabilised)
Corrosion / chemicalnone — rusts without protection
Relative cost1.0× of a standard 52100 bearing

Why 100Cr6 / 52100 in electric motors

What the material does that a standard chrome steel bearing does not.

The bearing in a motor is rarely load-limited. It is grease-life and noise limited, and 52100 is the grade those two limits were written around: a fine, homogeneous structure takes a mirror finish, which keeps the vibration level low, and the through-hardened ring holds its fit on an aluminium end shield without yielding. The material question only becomes interesting when the housing passes 120 °C or the drive puts a voltage on the shaft.

Where it sits on the machine

Position, bearing type and the material call for each one.
PositionBearing typeMaterial / finishWhy it works there
Drive end (locating)Deep groove ball52100, CN or C3, 2Z / 2RSTakes the residual axial load from the rotor and any belt pull, and fixes the shaft position.
Non-drive end (floating)Deep groove ball52100, C3, one side shieldedOuter ring is free to creep axially, so thermal growth of the shaft does not preload the pair.
Large frame, belt driveCylindrical roller52100, NU type, C3Radial capacity for belt pull; NU floats, so no axial load crosses the bearing.
Brake motor, tail endDeep groove ball52100, C3, 2RSKeeps grease in and brake dust out of the raceway.

Material alternatives for this duty

The same position, three ways — and what each one costs you.
MaterialFit hereChoose it when
100Cr6 / 52100Best fitCost, capacity and noise are all best in class below 120 °C. The default.
Si3N4Workable alternativeVFD-driven motors where shaft voltage erodes the raceway, or speed × bore beyond the steel-ball grease limit.
440CWorkable alternativeWashdown motors in food plant, where a rust film on the rings would contaminate the line.

What it will not do here

The limits that turn a good material choice into a warranty claim.
  • No corrosion protection. A motor idling in a damp plant rusts the races before it wears them — specify 2RS or a coated ring, not a longer grease interval.
  • Above 120 °C the standard temper is lost and the rings grow. Only dimensionally stabilised (S1/S2) 52100 belongs in a hot housing.
  • The bearing is not the place to absorb misalignment. A warped end shield spalls the raceway edge long before the L10 life is reached.

How to write it on the RFQ

Four lines, and the quotation stops being ambiguous.
  1. Bearing designation with the clearance class: 6205 C3, not just 6205.
  2. Shaft and housing fits, or the measured clearance after mounting, so the class can be checked against the real interference.
  3. Grease: base oil viscosity, thickener, fill percentage — or the OEM grease name if this is a service part.
  4. Noise requirement for service replacements: dBA at 1,500 rpm, or a vibration grade such as Z3/V3.

Frequently asked questions

Why do motor bearings fail at the outer ring first?

In a locating position the outer ring is stationary and takes the fit load, so the same spot passes under the ball every revolution. Electrical discharge and false brinelling from standstill vibration both show up there first.

Can a 6205 C3 be replaced with a C0?

Not in a motor with an aluminium end shield. The housing expands more than the steel ring, clearance is lost, and the bearing runs preloaded and hot. Keep the class, or measure the fits and let us recalculate.

Do hybrid bearings stop VFD damage?

They stop the discharge through that bearing, because the ceramic ball insulates the rotor from the frame. The voltage still exists and finds another path, so one hybrid end plus a shaft grounding ring is the reliable combination.